Parameters:
-
Temperature
measuring range: -60 ~ 125 ℃
-
Temperature measuring accuracy: 0.1 ℃
-
Control accuracy: 0.1 ℃
-
Input voltage: 220V AC
-
Measuring inputs: NTC (10K) waterproof
sensor
-
Output: 220V AC
-
Suitable for greenhouse seedling-raising,
propagation, and home heating ect.
Instructions
The window displays the current temperature
after powered, long press Ent button to turn off the thermostat, press the Ent
key once again to start. Press the Set button it will displays the setting temp
and flashes, press ▲ ▼ to set the temperature, then press Set or Ent to save parameters
and return main interface.
Long press Set button for 5 seconds to
enter setting menu, press ▲ ▼ button to switch to P0 ~ P7, press the Ent or 10 seconds no
action,it will save parameters automatically and return to the main interface.
P0 cooling, heating mode
Press Set button for 5 s to display P0,
then press the Set button to display the [H], Press ▲ ▼ to switch to [H-heating
mode] [C-cooling mode], then press Set to return to P0, press Ent to save
parameters and return to the main interface .
P1 temp difference setting
Press Set button for 5 s to display P0,
press ▲ ▼ to switch to P1, then press Set button to enter the temp difference
setting, press ▲ ▼ to set the temp difference, the range is 0.1 ~ 30 ℃, then press
Set to return to P1, press Ent to save parameters and return to the main
interface.
P2 temp upper limit setting
Press Set button for 5 s to display P0,
press ▲ ▼ to switch to P2, press Set to enter the temp upper limit setting,
press ▲ ▼ to set the temp limit setting range is -55 ~ 125 ℃, then press
Set to return P2, press Ent to save parameters and return to the main
interface.
P3 temperature lower limit setting
Press Set button for 5 s to display P0,
press ▲ ▼ to switch to P3, press Set to enter the temp lower limit setting,
press ▲ ▼ to set the temp limit setting range is -60 ~ 120 ℃, then press
Set to return P3, press Ent to save parameters and return to the main
interface.
P4 temperature calibration
When measuring temp and the standard temp
are deviated, or you have special needs, you can use this function to calibrate.
Press Set button for 5 s to display P0, press ▲ ▼ to switch to P4,
press Set button to enter temperature calibration settings, press ▲ ▼ to set the temp
range of -10 ~ 10 ℃, then press Set button to return P4, press Ent to save parameters
and return to the main interface.
P5 start delay setting
Press Set button for 5 seconds to display
P0, press ▲ ▼ to switch to P5, press Set to enter the start delay setting, press ▲ ▼ key to set the
delay time, the range is 0-10 minutes, then press the Set return to P5, press
Ent to save parameters and return to the main interface.
P6 high temp alarm settings
Press Set button for 5 s to display P0,
press ▲ ▼ to switch to P6, press Set button to enter the high temp alarm
condition setting, press ▲ ▼ to switch to ON, then press Set button to enter the high temp alarm
settings, setting range is -50 ~ 125 ℃, press the Set
button to return to P6, press Ent to save parameters and return to the main
interface.
P7 button lock
Press Set button for 5 seconds to display
P0, press ▲ ▼ to switch to P7, press Set button to enter the settings, press the ▲ ▼ button to set ON /
OFF, press the Set button to return to P7, press Ent to save parameters and
return to the main interface.
Package include:
-
1x Digital thermostat (Flat Plug)